Mes
HomeCompanyProducts & ServicesResource CentreClientsCareersContact
     
 
COMPREHENSIVE PORTABLE ANALYSER RANGE
 
ALM 32
For all 3-ph unbalanced basic, energy, power and electrical measurements
For comprehensive power quality studies - complete PQ measurements with transients & harmonics upto 50th order
Waveform displays, upto 4 MB memory & any-parameter-event capturing features are available
 
ALM 30
For all 3-ph unbalanced basic, energy, power and electrical measurements
For comprehensive power quality studies - complete PQ measurements with harmonics upto 50th order
Waveform displays, upto 2 MB memory & any-parameter-event capturing features are available
 
ALM 10
For 1-ph & 3-ph balanced basic, energy, power and electrical measurements
For comprehensive power quality studies - complete PQ measurements with harmonics upto 50th order
Waveform displays, upto 2 MB memory & inrush current capture features are available
 
ALM 8
 
For 1-ph & 3-ph balanced basic, energy, power and electrical measurements
For comprehensive power quality studies - complete PQ measurements with harmonics upto 50th order
Data display, upto 99 instant record capture & inrush current capture features are available
 

KRYKARD Portable range of Load Managers includes analysers that are cost-effective 1-phase models to comprehensive 3-phase models for in-depth energy audit and power quality studies.

FEATURES
Type of Measurement
3 CT
3 CT
1 CT - for balanced systems
1 CT - for balanced systems
.
.
.
.
.
Parameters Measured
.
.
.
.
Voltages
Y
Y
Y
Y
Currents 
Y
Y
Y
Y
kW, kVA, kVAr
Y
Y
Y
Y
Nuetral Current
Y
Y
.
.
kWh
Y
Y
Y
Y
kVArh
Y
Y
Y
Y
kVAh
Y
Y
Y
Y
Average, Min, Max values
Y
Y
Y
Y
Peak V and I
Y
Y
Y
Y
Export & Import
Y
Y
Y
Y
Hz
Y
Y
Y
Y
.
.
.
.
.
Power Quality
.
.
.
.
Crest Factor for V & I
Y
Y
Y
Y
K-factor for I
Y
Y
Y
Y
THD for V & I
Y
Y
Y
Y
Harmonics for V, I
upto 50th
upto 50th
Upto 50th
Upto 50th
Harmonics for Power
upto 50th
.
.
.
Waveform display
multiple waveforms
multiple waveforms
multiple waveforms
.
Transients
50 records
.
.
.
Distortion Factor
Y
Y
Y
Y
Displacement PF
Y
Y
Y
Y
Tan 
Y
Y
Y
.
Phase angles
Y
Y
.
.
Vector Diagrams
Y
Y
.
.
Bargraph display
Y
Y
Y
.
.
.
.
.
.
Measurment details
.
.
.
.
Multi-tasking (viewing while recording)
Y
Y
Y
Y
Samples/ cycle
256
256
256
256
Sampling periodicity
continuous
continuous
Continuous
Continuous
Sampling for harmonics
continuous
continuous
Continuous
Continuous
Connection type
3ph 3/ 4wire
3ph 3/ 4wire
3 ph balanced/ 1phase
3 ph balanced/ 1phase
Accuracy 
Class 1.0
Class 1.0
Class 1.0
Class 1.0
.
.
.
.
.
Alarms
.
.
.
.
Max
Yes
Yes
Yes
.
Min
Yes
Yes
Yes
.
Threshold limit programming
Yes
Yes
Yes
.
Hysterisis programming
Yes
Yes
Yes
.
Alarm duration
Yes
Yes
Yes
.
Alarm records
4096 records
4096 records
4096 records
.
Alarm resolution
1/2 cycle (10ms)
1/2 cycle (10ms)
1/2 cycle (10ms)
.
Inrush current measurement
.
.
Yes
Yes
.
.
.
.
.
Other Features
.
.
.
.
Display
Color Graphic LCD
Color Graphic LCD
Colour Graphic LCD
Backlit LCD
Internal battery backup
Upto 8 hours
Upto 8 hours
Upto 8 hours
Upto 40 hours (non-rech)
Memory
4 MB
2 MB
1.5 MB
99 snaphots
User defined recording modes
4
4
4
.
Programmable log interval
Yes
Yes
Yes
.
Screen shots in memory
12
8
8
99 Snapshots
Trending on screen
Yes
Yes
Yes
Options of CTs
5/100; 200; 1000; 6500
5/100; 200; 1000; 6500
5/100; 200; 1000; 6500
5/100; 200; 1000; 6500
Ampflex CT option for busbar measurements
Yes
Yes
Yes
Yes
Printer
External option
External option
External option
No
 
     
     
     
     
     
   
copyright - Manaco , 2006 - 07
     