Mes
HomeCompanyProducts & ServicesResource CentreClientsCareersContact
     
   
 

Salient Features – PLM Cube 300

  • kWh & kW Meter - Accuracy better than Class 1
  • DIN 96x96 Standard meter
  • Large Clear LCD display with direct energy reading
  • RS-485 serial port with Modbus RTU protocol
  • Isolated kWh pulse output
  • Suitable for both 3-phase 3 or 4 wire configurations
  • Continuous parallel sampling with high sampling rate - ideal even on non-linear loads
  • Safe to use fully isolated CT inputs makes it ideal even on poor power quality conditions

Salient Features – PLM Cube 310

  • kWh & kW Meter - Accuracy better than Class 1
  • DIN 96x96 Standard meter
  • Large Clear LCD display with direct energy reading
  • RS-485 serial port with Modbus RTU protocol
  • Isolated kWh pulse output
  • Suitable for both 3-phase 3 or 4 wire configurations
  • Continuous parallel sampling with high sampling rate - ideal even on non-linear loads
  • Safe to use fully isolated CT inputs makes it ideal even on poor power quality conditions
  • Dual kWh reading for dual tariff applications
  • Trigger through external signal from DG of 230V

 

Specifications

INPUTS

  • Voltage 400/230V - 3 Phase 3 or 4 Wire
  • Current 5A from external CTs. 1A optional
  • Fully isolated @2.5kV Voltage measurement range 50% to 120%
  • Current measurement range 0.2% to 120%
  • Frequency Range - Fundamental 45 to 65Hz
  • Suitable for waveforms containing harmonics up to 20th order
  • Burden on Voltage input <0.1VA per phase
  • Burden on Current input <0.1VA per phase
  • Overload on Voltage x4 for 1 hour
  • Overload on Current x40 for 0.5 second max
  • CT Primary programmable from 10A to 25kA
  • VT primary programmable from 11V to 55kV

DISPLAY

  • Type Custom, Supertwist, LCD
  • Data Retention 10 years min. Stores kWh & Meter set-up Form at 8       x 6.66mm high digits with DPs & 3.2mm legends
  • Legends Wh, kWh, MWh etc. depending on user settings

AUXILIARY SUPPLY

  • Standard 230V 50/60 Hz ±15% (Options 110V 50/60 Hz ±15%)
  • Load 2VA max; Overload x1.2 continuous

ACCURACY

  • kWh Better than Class 1 per EN 61036 & EN 62053-21
  • kW Better than ±1% reading

PULSE OUTPUT

  • 1 Pulse per unit of kWh
  • Scaling Settable between 1 & 1000 counts of kWh register
  • Pulse Period 0.1 sec. Default
  • Settable between 0.1 and 20 sec
  • Rise & Fall Time < 2.0ms
  • Type N/O Volt free contact. Optically isolated BiFET
  • Contacts 100mA ac/dc max., 100V ac/dc max.

MODBUS RTU Serial Communication port

  • Protocol: MODBUS® RTU with 16 bit CRC
  • Baud Rate: 4800, 9600 or 19,2000 User settable
  • Latency Reply within 250ms max
  • New query within 5ms of previous one

GENERAL

  • Temperature Operating -10°C to +65°C
  • Humidity < 75% non-condensing
  • Environment IP54 standard, Ip65 optional

MECHANICAL

  • Terminals Rising Cage. 4mm cable max
  • Dimensions 96 x 96 mm x 83.5 mm
  • Weight: 250 gms
 
PLM 300
     
     
     
     
     
   
copyright - Manaco , 2006 - 07
     
Design By : bluebeam.in