Mes
HomeCompanyProducts & ServicesResource CentreClientsCareersContact
     
 
3-LEVEL ENERGY MANAGEMENT WITH KRYKARD
 
FOR INCOMER PANELS AND CRITICAL LOCATIONS
PLM Cube 515
PLM Cube 515 with Ethernet port & Memory
PLM Cube 515 with DI / DO
 
FOR OUTGOING FEEDERS & SUB-FEEDERS
FOR HARMONIC FEEDERS & LOADS
   
PLM Cube 415
PLM Cube 515
PLM Cube 410
PLM Cube 510
   
FOR LOADS
FOR DG SETS
PLM Cube 410
PLM Cube 410
PLM Cube 300
PLM Cube 310 - Dual Tariff Meters
PLM Cube 300
   

COMPARISION CHART BETWEEN KRYKARD PLM CUBE SERIES

 
FEATURES
Parameters
.
.
.
.
.
.
Voltages
.
 
Y
Y
Y
Y
Peak voltages
.
 
Y
Y
Y
Y
Currents
.
 
Y
Y
Y
Y
Peak currents
.
 
Y
Y
Y
.Y
Neutral current
.
 
Y
Y
Y
Y
PF
.
 
Y
Y
Y
Y
kW
Y
Y
Y
.
.
Y
kVA, kVAR
.
 
Y
Y
Y
Y
Hz
.
 
Y
Y
Y
Y
kWh
Y
Y
Y
Y
Y
Y
Dual kWh (For DG applications)  
Y
Y
Y
Y
Y
kVAh, kVARh
.
 
Y
Y
Y
Y
Run hours (settable)
.
 
Y
Y
Y
Y
THD of V and I
.
 
Y
Y
Y
Y
Demand on V & I      
Y
 
Y
Demands on kW, kVA, kVAR
.
.
 
.Y
 
Y
MD on kW, kVA, kVAR
.
.
 
.Y
 
Y
Individual Harmonics V & I upto 15th
.
.
 
 
Y
Import / Export measurements
.
.
 
.
 
Y
.
.
.
.
.
.
 
Installation
.
.
.
.
.
 
CT programming
Y
Y
Y
Y
Y
Y
PT programming
Y
Y
Y
Y
Y
Y
CT isolation
2.5kV
2.5kV
2.5kV
2.5kV
2.5kV
2.5kV
Over current
x 40 for 1s
x 40 for 1s
x 40 for 1s
x 40 for 1s
x 40 for 1s
x 40 for 1s
Suitable for 3/4wire
Y
Y
Y
Y
Y
Y
Size
96x96mm
96x96mm
96x96mm
96x96mm
96x96mm
96x96mm
Aux Supply
230Vac +/- 15%
230Vac +/- 15%
230Vac +/- 15%
230Vac +/- 15%
230Vac +/- 15%
230Vac +/- 15%
Temperature
-10 to 65c
-10 to 65c
-10 to 65c
-10 to 65c
-10 to 65c
-10 to 65c
Protection
IP54
IP54
IP54
IP54
IP54
IP54
.
.
.
.
.
.
.
Display
.
.
.
.
.
.
Display type
Large LCD
Large LCD
Large backlit LCD
Large backlit LCD
Large backlit LCD
Large backlit LCD
Parameter display
1 line
1 line
3 line
3 line
3 line
3 line
Password Protection    
Y
Y
Y
Y
.
.
.
.
.
.
.
Measurement
.
.
.
.
.
.
True RMS
Upto 20th harmonic
Upto 20th harmonic
Upto 30th harmonic
Upto 30th harmonic
Upto 30th harmonic
Upto 30th harmonic
Measurement method
continuous parallel
continuous parallel
continuous parallel
continuous parallel
continuous parallel
continuous parallel
Accuracy (Standard)
Class 1.0 - IEC 1036
Class 1.0 - IEC 1036
Class 1.0 - IEC 1036
Class 1.0 - IEC 1036
Class 1.0 - IEC 1036
Class 1.0 - IEC 1036
Accuracy (Optional)    

Class 0.5 -IS 14779

Class 0.5 -IS 14779 Class 0.5 -IS 14779 Class 0.5 -IS 14779
PF range
0 lag to UPF to 0 lead
0 lag to UPF to 0 lead
0 lag to UPF to 0 lead
0 lag to UPF to 0 lead
0 lag to UPF to 0 lead
0.1 lag to UPF to 0.1 lead
.
.
.
.
.
.
.
Communication
.
.
.
.
.
.
RS485 port
Modbus RTU
Modbus RTU
Modbus RTU
Modbus RTU
Modbus RTU
Modbus RTU
User programmable registers
.
Y
Y
Y
Y
Fast communication
Y
Y
Y
Y
Y
Y
Pulse output
kWh & kVARh
kWh & kVARh
kWh & kVARh
kWh & kVARh
kWh & kVARh
kWh & kVARh
Digital inputs
.
.
.
Y
Digital outputs
.
.
.
Y
.
.
.
.
.
.
.
Testing & Diagnostics
.
.
.
.
.
.
Pulse test facility
Y
Y
Y
Y
Y
Y
Communications diagnostics LED
Y
Y
Y
Y
Y
Y
 
     
     
     
     
     
   
copyright - Manaco , 2006 - 07
     
Design By : bluebeam.in